Pump Sentinel Inventory Control (FIC) System

Model#:

3110-009 - Sentinel Console

Systems: Sentinel FIC System

Features:

  • Prevents fluid theft by using switches to enable or disable
    up to six pumps
  • Master key needed to turn system on
  • 6′ cable to run to junction box
  • Small Console footprint: 6.5″ L x 5″ W x 3″ H

Pump Sentinel Component Specifications:

 

Function Prevents fluid spills during nonworking hours by using a built in timer to turn off air supply to all pumps at a predetermined time each day.
Power 120 VAC, 60/50 Hz, 50 Watts

Requirements & Limitations
  • No.18 AWG wire is recommended for all runs less than 400 feet.
  • For runs from 400 to 625 feet, use wire No.16 AWG or larger.
  • 24VDC wiring can be run around the overhead structure of the building without using conduit.